Open Access   Article Go Back

Improvement of Power Quality in an Autonomous System using DSATCOM

Sourav Ghosh1 , Saumyadeep Mahata2 , Epsita Das3 , Ambarnath Banerji4

Section:Research Paper, Product Type: Journal Paper
Volume-04 , Issue-06 , Page no. 149-151, Aug-2016

Online published on Sep 03, 2016

Copyright © Sourav Ghosh, Saumyadeep Mahata, Epsita Das, Ambarnath Banerji . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

View this paper at   Google Scholar | DPI Digital Library

How to Cite this Paper

  • IEEE Citation
  • MLA Citation
  • APA Citation
  • BibTex Citation
  • RIS Citation

IEEE Style Citation: Sourav Ghosh, Saumyadeep Mahata, Epsita Das, Ambarnath Banerji, “Improvement of Power Quality in an Autonomous System using DSATCOM,” International Journal of Computer Sciences and Engineering, Vol.04, Issue.06, pp.149-151, 2016.

MLA Style Citation: Sourav Ghosh, Saumyadeep Mahata, Epsita Das, Ambarnath Banerji "Improvement of Power Quality in an Autonomous System using DSATCOM." International Journal of Computer Sciences and Engineering 04.06 (2016): 149-151.

APA Style Citation: Sourav Ghosh, Saumyadeep Mahata, Epsita Das, Ambarnath Banerji, (2016). Improvement of Power Quality in an Autonomous System using DSATCOM. International Journal of Computer Sciences and Engineering, 04(06), 149-151.

BibTex Style Citation:
@article{Ghosh_2016,
author = {Sourav Ghosh, Saumyadeep Mahata, Epsita Das, Ambarnath Banerji},
title = {Improvement of Power Quality in an Autonomous System using DSATCOM},
journal = {International Journal of Computer Sciences and Engineering},
issue_date = {8 2016},
volume = {04},
Issue = {06},
month = {8},
year = {2016},
issn = {2347-2693},
pages = {149-151},
url = {https://www.ijcseonline.org/full_spl_paper_view.php?paper_id=141},
publisher = {IJCSE, Indore, INDIA},
}

RIS Style Citation:
TY - JOUR
UR - https://www.ijcseonline.org/full_spl_paper_view.php?paper_id=141
TI - Improvement of Power Quality in an Autonomous System using DSATCOM
T2 - International Journal of Computer Sciences and Engineering
AU - Sourav Ghosh, Saumyadeep Mahata, Epsita Das, Ambarnath Banerji
PY - 2016
DA - 2016/09/03
PB - IJCSE, Indore, INDIA
SP - 149-151
IS - 06
VL - 04
SN - 2347-2693
ER -

           

Abstract

This paper discusses an control scheme of a Distribution Static compensator (DSTATCOM) to rectify unbalance and improve power quality by reducing harmonics at load end of an autonomous system. This scheme does not require any new hardware implementation. In this proposed technique.Three phase load current active and reactive components are dissociated and are used in association with PI controllers and simple arithmetical operators produces carrier signals for and PWM controller. This signal along with the sinusoidal voltage is used to generate firing pulses for the IGBT switches of a 3 level voltage source inverter (VSI). The result shows that the scheme is effective in reducing total harmonic distortion (THD) in voltage at PCC, load current and competent to overcome unbalance at load end.

Key-Words / Index Term

DSTACOM; PCC; PI controller; PWM controller; VSI

References

REFERENCES
[1] J. Ehnberg, “Autonomous Power Systems based on Renewables on Generation Reliability and System Controls”, Thesis for degree of Doctor of Philosophy, Division of Electric Power Engineering, Department of Energy and Environment, Chalmers University of Technology, Göteborg, Sweden,2007.
[2] Y. Hu, Z.Chen,” Dynamic Control of An Autonomous Power System with Power Electronic Converters”, 5th International Conference on Power Electronics and Drives System, PEDS 2003, vol. 2,pp. 1564-1569.
[3] K. Kant, S. R. Arya, B. Singh, “Voltage Sensor less Control Algorithm for Power Quality Improvement in Distribution Network “, Power Systems Conference (NPSC), Dec 2014,pp. 1-6.
[4] H. Akagi and H. Fujita, “A New Power Line Conditioner for Harmonic Compensation in Power Systems,” IEEE Trans. Power Delivery, vol. 10, no. 3, pp. 1570–1575, Jul. 1995.
[5] B. Singh, J. Solanki, “ Load compensation for Diesel Generator-Based Isolated Generation System Employing DSTATCOM”, IEEE transactions on Industry Applications, vol. 47, pp. 238-244.
[6] A. Chandra, B. Singh, B. N. Singh, and K. Al-Haddad, “An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads,” IEEE Trans. Power Electron., vol. 15, no. 3, pp. 495–507, May 2000.
[7] A. K. Ziarani and A. Konrad, “A method of extraction of non stationary sinusoids,” Journal of Signal Process., Elsevier, vol. 84, no. 8, pp. 1323–1346, Aug. 2004.
[8] T. Al Chaer, J. P. Gaubert, L. Rambault, and M. Najjar, “Linear feedback control of a parallel active harmonic conditioner in power systems,” IEEE Trans. Power Electron., vol. 24, no. 3, pp. 641–653, Mar. 2009.
[9] S. George, V. Agarwal, ”A Novel, DSP Based Algorithm for Optimizing the Harmonics and Reactive Power Under Non-Sinusoidal Supply Voltage Conditions”, IEEE Transactions on Power Delivery, vol. 20, no. 4, Oct. 2005, pp. 2526-2534.